  • The installation techniques and precautions in this manual can help you avoid any unnecessary damage or frustration.More information please refer to :.
  • Please visit our website for technical support and we are likely to answer or solve all the questions for you!
  • Copyrighted by “Shenzhen Anycubic Technology Co., Ltd”, all rights reserved.
  • Please contact our customer service first if you have any issue after receiving the products.The washing liquid should be sealed and stored in a cool and dry place after use.
    • After cleaning, the models need air-dried before putting in the curing chamber. Be cautious when using the scraper. Never direct the scraper towards your hands.In case of emergency, please immediately cut off the power of ANYCUBIC machine and contact thetechnical support.
    • Working outside those limits may result in low quality performance. Do not disassemble ANYCUBIC machine, please contact technical support if you have any question. ①Anti-UV lid – blocks 99.995% of UV light and plays a protective role. ②Control panel – touch it to control the machine.
    • ④Air vent – there is a fan inside to dissipate heat.
    • ⑥Power switch – turn on/off the machine. ⑦Power socket – to connect the external adapter.
    • This machine has two working modes, wash and cure. The following describes the basic functions and operation precautions in different working modes.
  • ①Plug in the power ②Turn on the machine ③The default mode is curing.
  • Place the washing bucket firmly on the platform by the indentation.(Note: The curing table must be took off if it is on the platform.).
    • Then please use the platform holder to secure the platform as shown below.Choose the suitable platform holder:① Adjustable platform holder – Suitable for model with height less than 115mm.② Platform holder – Suitable for models with height greater than 115mm and less than 165mm.Case 2: The printed objects has been removed from the platform (suitable for small models).
    • If the objects are less than 18mm, please do not remove them from the platform, and refer to the instructions on the leftto clean them with the platform.If you use another platform holder, you just need to fix it directly to the machine.Tip: the washing liquid can be alcohol, detergent solution, etc.
  • (If the lid has been removed during the operation, the program will be paused. And the program will resume after cover back the lid.).
  • After the model is washed, it issuggested to air dry the model before proceeding to the next post-cure process.
  • It is suggested to air dry the model before proceeding to the post-cure process. Switch the machine to cure mode by touching the Mode on the front panel.
    • Place the objects on the curing tableand cover the lid. Select the curing time. (Generally, if a model has a diameter of less than 30mm, it is recommended to have a curing time of 2 minutes.
    • And the program will resume after cover back the lid. In order not to affect the curing effect, please do not remove the lid during the curing process.②The temperature of the front side of the lid will be slightly higher than room temperature because of the direct UV light.③Do not look directly at the UV light during the curing process, although the lid has blocked 99.995% of the UV light.
      • Here we take “alcohol“ as the washing liquid for example. ① After used for cleaning about 30 models, the alcohol might become muddy, as shown above.
      • ③ Pour the top layer of alcohol into another container and then dispose the residue, e.g. expose the residue in the sunlight until the alcohol is.
      • ④ After disposing the waste, rinse the washing bucket several times with water; if the sediment at the bottom of the bucket is too viscous, remove the bucket rotor and brush them.
      • ⑤ After cleaning the bucket, pour the filtered alcohol into the washing bucket and covered with lid for future use. The filtered alcohol may still contain dissolved resin, but it can be used to wash the printed.
      • If the rotor rotates abnormally after long-term use, you can replace the stainless steel bearing in the rotor (there is 1pcs spare bearing in the package).
      • The machine does not work.① Poor power contact.
      • Try again after cover the lid. The rotor inside the washing bucket does not rotate during the washing process.① The rotor inside the washing bucket does not move because it is caught by foreign matter.
      • Then turn on the power to wash the model again.② There are too much precipitation in the washing liquid, please change the washing liquid and clean the bucket and rotor.
      • Inject normal grease into the oil hole of the motor.③ The screw on the rotor is loose during the washing process. Fix the screw to the rotor.
  • Wash with more than 95% alcohol.② Curing is performed immediately after the model is washed. It needs to wait for the model to air dry before putting it into the machine for curing.
  • Thank you for purchasing ANYCUBIC products! Under normal usage and service, the products and its parts have a warranty period up to one year.
  • Our professional after-sale service team would response within 24 hours and help you to solve the issue. Anycubic Wash and Cure User Manual – Download [optimized]Anycubic Wash and Cure User Manual – Download.
    • Before using: ensure the antenna has been installed.
    • The name and format of the file WIFI.txt cannot be changed.b. The account and password should not contain exotic letters and should not be more than 20 characters.c. If the WIFI doesn’t have a password, enter NONE in ‘WIFI Password” and 0 in ‘Settings”; otherwise, enter I in “Settings”.d.
    • Those punctuation marks must not be deleted. 2) Add the device on APP:. Check IP address of the device.
  • Connect the device:. The smartphone and 3D printer must connect to the same WIFI.b.
    • Click “File” on the bottom menu bar, check and preview the model file on a USB memory stick that is connected to a 3D printer.
    • Click to select the model and then click the image . on the right side of the Ale to enter the Print interface.
    • Start, pause and stop. Click the icon on the top right corner to set printing parameters.
    • 1Documents / Resources.
      T0 Sensor Abnormal